Technical
Specifications |
Declared
by the manufacturer |
Values
measured in our tests |
Dimensions |
diameter 20
mm, length 256 mm |
Confirmed
|
Microphone |
super-cardioid/lobar
|
Confirmed
|
Frequency response |
40 Hz to 20
kHz |
Confirmed
|
Max. sound pressure level
with Phantom
|
132 dB SPL
at P48 |
Confirmed +/- 0,75 %
variation ) |
Max. sound pressure level
with battery
|
126 dB SPL |
128,25 dB SPL
|
Weight |
128 g
(without battery) |
Confirmed
|
Sensitivity in free field,
no load (1kHz) |
21 mV/Pa at
P48; 19mV/Pa with battery powering |
Confirmed +/- 1,75 %
variation ) |
Equivalent noise level |
15 dB (A) at
P48; 16 dB (A) with battery powering |
Confirmed +/- 2,25 %
variation ) |
Operating time |
approx. 150 hrs |
|
Power supply external
Phantom
|
48 V +/- 4V
(P48, IEC 61938)
|
Confirmed
|
Power supply internal 1
|
Standard
Alkaline 1,5 V AA size ( not rechargeable )
|
Confirmed
|
Power supply internal 2
|
Rechargeable
1,2 V AA size ( See note
operating time ! )
|
Confirmed
|
Current consumption |
4,4 mA at
P48 |
4,25
mA at P48 ( Phantom supply )
|